Polycom SR12 Speaker System User Manual


 
Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 112
Description
This parameter selects the method for obtaining the IP address of the ethernet
port.
eth_mac Get Ethernet MAC Address
Description
This parameter gets the MAC address for the system's Ethernet port. The value
will be formatted in all lowercase with bytes separated by a colon, for example
“00:04:f2:bf:00:01”.
Examples
ir_key_press Key Pressed On IR Remote
Description
When queried, this parameter returns the keycode value of the last key that
was pressed on the IR remote. As an event, a status message is generated
whenever a key is pressed on the IR remote.
Argument Argument value
Channel Type Device-Specific System
Value Type String
Read/Write Mode Read-Only
System Limits Max String Length: 17
Command Response Description
get eth_mac 1 val eth_mac 1
"00:04:f2:bf:00:01"
Queries the ethernet mac address on device 1.
Argument Argument value
Channel Type Virtual Channel
Value Type Integer
Read/Write Mode Read-Only
Phys Chans Infrared Remote Input
Virt Chans Control
System Limits Minimum: 0, Maximum: 255