Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 96
sig_gen_sweep_stop Signal Generator Sweep Stop Frequency
Description
When the signal generator’s sig_gen_type is set to sweep, the parameter sets the
frequency (in Hz) at which the sweep generator stops. The direction of the
frequency sweep will be up or down depending on whether the
sig_gen_sweep_start parameter is higher or lower than this parameter.
sig_gen_sweep_time Signal Generator Sweep Time
Description
When the signal generator’s sig_gen_type is set to sweep, this parameter sets
the duration (in milliseconds) that the sweep generator takes to sweep from its
start frequency to its stop frequency.
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read/Write
Phys Chans Signal Generator
Virt Chans Mono
System Limits Minimum: 20.0, Maximum: 20000.0, Resolution: 0.1
Default 20000.0
User Limits
Supported
No
Argument Argument value
Channel Type Virtual Channel
Value Type Integer
Read/Write Mode Read/Write
Phys Chans Signal Generator
Virt Chans Mono
System Limits Minimum: 10, Maximum: 60000
Default 10000
User Limits
Supported
No