Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 104
Examples
am_hold_time Automixer Hold Time
Description
This parameter defines how long (in ms) the microphone in the specified
automixer group will be considered active after the last detected significant
level on the microphone.
am_last_mic_mode Automixer Last Mic Mode
Description
When this parameter is set to 1, the last mic mode is enabled on the
microphone.
Command Response Description
set am_group "Table Mic
1" 1
val am_group "Table Mic
1" 1
Assigns "Table Mic 1" to automixer group 1.
Argument Argument value
Channel Type Global Systems
Value Type Integer
Read/Write Mode Read/Write
Indices 1-63 : group number
Systems Limits Minimum: 10, Maximum: 10000
Default 500
User Limits
Supported
No
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans Mono, Stereo
Default 0