sig_gen_sweep_start Signal Generator Sweep Start Frequency
Description
When the signal generator’s sig_gen_type is set to sweep, this parameter sets
the frequency (in Hz) at which the sweep generator begins. The direction of the
frequency sweep will be up or down depending on whether this parameter is
higher or lower than the sig_gen_sweep_stop parameter.
sig_gen_sweep_step Signal Generator Sweep Step Size
Description
When the signal generator’s sig_gen_type is set to sweep, this parameter sets
the step size of the sweep generator. This signal generator can sweep
continuously, in fractional octave steps, or in full octave steps.
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read/Write
Phys Chans Signal Generator
Virt Chans Mono
System Limits Minimum: 20.0, Maximum: 20000.0, Resolution: 0.1
Default 20.0
User Limits
Supported
No
Argument Argument value
Channel Type Virtual Channel
Value Type List
Read/Write Mode Read/Write
Phys Chans Signal Generator
Virt Chans Mono
Values continuous : Continuous (default)
1/24 : 1/24 Octave
1/12 : 1/12 Octave
1/6 : 1/6 Octave
1/3 : 1/3 Octave
1 : 1 Octave