Connectionfortheautotimeadjustmentfunction(1)
When "Master" is set for "Auto time adjustment" on the [Time & date] tab under the "Basic" page of the setup menu
"Time adjustment signal output" becomes available and the clock of this recorder will be applied to other devices.
The time adjustment signal output will be generated from pin no. 20 (time adjustment I/O) at the time set for "Activation time"
Connectionfortheautotimeadjustmentfunction(2)
When"Slave"issetfor"Autoadjustmenttime"onthe[Time&date]tabunderthe"Basic"pageofthesetupmenu
"Time adjustment signal input" becomes available and the clock of the other device will be applied to this recorder.
When a signal output from the other device is supplied to the time adjustment I/O terminals (pin no. 20) 15 minutes before/after
the time set for "Activation time", the clock of the recorder will be set to the time set for "Activation time".
Example:
When "15:00" is set for "Activation time"
• Signalissuppliedat2:50:00(hour:minute:second)pm Set at 3:00:00 pm
• Signalinputsuppliedat3:14:45pm Set at 3:00:00 pm
• Signalissuppliedat3:20:00pm Time will not be adjusted.
Important:
• When"Slave"isselected,theclockwillnotbeadjustedduringeventrecordingoremergencyrecording.
13 20
ALARM/CONTROL
Signal ground
Sensor signal input
Alarm input
Alarm reset input
Series recording output
Time adjustment signal input
Signal ground
Alarm output
Alarm reset output
Alarm recording
During recording
Disk
Buzzer output
System error output
Thermal error output
Time adjustment signal output
Series recording output
Output for the
indicators on
the front panel
Terminal of the other device
(Signal ground)
(Time adjustment signal output)
13 20
Signal ground
Sensor signal input
Alarm input
Alarm reset input
Series recording output
Time adjustment signal input
Signal ground
Alarm output
Alarm reset output
Alarm recording
During recording
Disk
Buzzer output
System error output
Thermal error output
Time adjustment signal output
Series recording output
Output for the
indicators on
the front panel
Terminal of the other device
ALARM/CONTROL
(Signal ground)
(Time adjustment signal output)