Panasonic WJ-HD200 Speaker System User Manual


 
64
8 Parity Check (PARITY CHECK)
NONE: No parity check
EVEN: Even parity
ODD: Odd parity
8 Stop Bit (STOP BIT)
1 bit: 1 bit
2 bit: 2 bits
8 Wait Time (WAIT TIME)
OFF: Retransmission is disabled.
100 MSEC: 100 m seconds
200 MSEC: 200 m seconds
1 SEC: 1 second
8 System Unit Address (SYSTEM UNIT ADDRESS)
(only for PS
DATA)
Assignable address: From 1 to 99, must be unique in
the chain.
8 Control Unit Address
(CONTROL UNIT ADDRESS) (only for PS
DATA)
Assignable address: From 1 to 99, must be unique in
the chain.
8 Alarm Data (ALARM DATA)
OFF: Select this when no system controller is connect-
ed.
0 SEC: Pauses no time.
1 SEC: Pauses for 1 second.
5 SEC: Pauses for 5 seconds.
Click the [SET] button if all are adequately set.
Click the [CAMERA NO. SETUP] button. The CAMERA NO.
SETUP window opens.
Communication Setup
COMMUNICATION SETUP
Click the [SERIAL SETUP], or [NETWORK SETUP] button.
The respective window opens.
Serial Port Setup
SERIAL PORT SETUP
8 Protocol Selection (PROTOCOL SELECT)
PS
DATA: Select when the communication chain uses
the PS
DATA protocol.
When selected, the DATA terminal on the rear panel
can be used.
VCR: Select when other than PS
DATA is used.
When selected, the RS-232C terminal on the rear
panel can be used.
8 Baud Rate (BAUD RATE)
4800: 4 800 bps
9600: 9 600 bps
19200: 19 200 bps
8 Data Bit (DATA BIT)
7: 7 bits
8: 8 bits; select 8 when using the VCR protocol.