Alarm Setup ALARM SETUP
The digital disk recorder accepts alarm signals supplied
from connected devices such as sensors or camera site
equipment. The recorder by itself also generates an alarm
signal when the preset motion detection is activated. Any
alarm signal starts recording with the preset recording
mode, field rate, and picture quality specified in the REC
MODE menu described earlier. Alarm recording stops
when the preset time has elapsed, the alarm [RESET] but-
ton on the front panel is pressed, or the ALARM RESET IN
is supplied from the connected device. The recorder out-
puts an alarm recovery signal from the rear panel.
Alarm Buzzer ALARM BUZZ
Buzzer beeping is enabled or disabled when an alarm
operates.
1. Move the cursor to ALARM BUZZ with the [D] or [C]
button.
2. Rotate the JogDial to select ON or OFF.
The default is ON.
ON: Buzzer beeps while alarm is active.
OFF: Buzzer does not beep.
Video Loss VIDEO LOSS
Video loss detection is enabled or disabled.
1. Move the cursor to VIDEO LOSS with the [D] or [C]
button.
2. Rotate the JogDial to select ON or OFF.
The default is ON.
ON: Enables the recorder to detect video loss.
OFF: Ignores video loss.
Monitor Mode MONITOR MODE
This setting specifies whether to allow the displayed picture
to change to the alarm activated channel when an alarm
operates.
1. Move the cursor to MONITOR MODE with the [D] or
[C] button.
2. Select the parameter with the JogDial, and press the
Jogdial.
The default is SPOT.
SPOT: Switches to the picture of the channel that the
alarm operates.
OFF: Retains the previous display mode.
Video Motion Detection VMD SETUP
A VMD or Video Motion Detector senses changes in the
video signals within a preset area and supplies alarm out-
put. When a change is detected, the recorder starts record-
ing. The detection sensitivity and area are selected on this
menu.
1. Move the cursor to VMD SETUPO with the [D] or [C]
button, and press the JogDial. The VMD SETUP window
opens.
2. Move the cursor to the desired line.
3. Rotate the JogDial to select the desired parameter, and
press the JogDial.
The default is OFF.
LOW: Low sensitivity.
MID: Medium sensitivity.
HIGH: High sensitivity.
OFF: Motion detection is disabled.
The area setup window appears with an asterisk when
other than OFF is selected. The asterisk represents the
upper-left or bottom-right of the detection area. The
division lines are not actually displayed on the monitor.
ALARM SETUP
ALARM BUZZ ON
VIDEO LOSS ON
MONITOR MODE SPOT
VMD SETUPO
VMD SETUP
CAM SENS
1 OFF
2 LOWO
3 MIDO
4 HIGHO
5 OFF
6 OFF
7 OFF
8 OFF