5.2.2 Configuration for communication with GX IEC Developer
Generally, positioning control is performed via a CC-Link network in applications where an addi
-
tional PLC system is used for automation tasks as well as the integrated controller in the ampli
-
fier. In this example we will thus only provide detailed descriptions of the settings required to
integrate the servo amplifier in your project.
Procedure:
How to open an existing project in GX IEC Developer:
ቢ
Select
Network
ᕡ in the project directory tree in the left window.
ባ
Select
CC-Link
ᕢ in the
Network Parameter
box.
ቤ
This opens the window
Network parameters: Setting the CC-Link list
where you can now
enter the settings shown in Fig. 5-6 ᕣ.
Positioning via a CC-Link Network CC-Link Communication Settings
MR-J3-T 5-35
Fig. 5-6: Settings required in GX IEC Developer for CC-Link communication between
the controller and the servo amplifier
ᕣ
ᕡ
ᕢ
(a)
(b)
(c)