Mitsubishi Electronics A8GT-J61BT15 Stereo Equalizer User Manual


 
4 - 14 4 - 14
MELSEC-GOT
4 MONITORING SPECIFICATION
4.6.1 Initial setting command
(1) Initial setting command
This is the initial setting command for monitoring with the GOT internal device.
Create a sequence program for initial setting command to be processed before
the commands described in Section 4.6.2 and after are executed.
(2) Command format
Transfer Direction Addresses Write data
RWwm (Higher byte) 1: Initial setting
RWwm (Lower byte)
1: Monitoring by the dedicated command monitor
method
2: Switch to the normal monitor method
Master station GOT
RWwm + 1 to RWwm + F
———
GOT Master station RWrn to RWrn + F
———
(3) Communication overview
PLC CPU
Master station
remote register
RWw0
TO
0101
H
RWw0
1) 2)
0101
H
GOT
remote register
1) Store the initial setting command data in the master station's remote register
(RWw).
2) Turn on the initial data setting request flag and store the command data in the
GOT remote register (RWw).
(Command execution)
The initial data setting complete flag turns on when the command processing
is complete.
By executing this command, the GOT will be in the monitor status with the
dedicated command monitor method.