4 - 2 4 - 2
MELSEC-GOT
4 MONITORING SPECIFICATION
(1) Normal monitor method
In the monitor overview, the remote output and remote register
(write area) are described
separately from the remote input and remote register (read area),
but all of the information
can be displayed on one screen for monitoring.
Monitor for remote output and remote register (write area)
1) Using the sequence program, the data is stored
in the remote output (RY) and the remote register
(RWw) of GOT's allocated to the master station.
2
) Data is stored in the GOT's remote output
and re-mote register by link scan.
3
) The specified remote output and remote register
aremonitored.
TO
RY
RWw
Master
station
PLC CPU
RY
RWw
2)
1)
2)
3)
GOT
Line1
Line2
Line3
500
350
100
450
400
100
The monitor point depending on the number of
occupied stations setting.
When 2 stations are set
RYn0 to RY(n+2)F:48 points
RWwm to RWwm+7:8 points
When 4 stations are set
RYn0 to RY(n+6)F:112 points
RWwm to RWwm+F:16 points
4