Output Wiring – Model 2700 Configurable I/O Transmitters
Output Wiring – Configurable I/O SpecificationsOutput Wiring – Fieldbus/PROFIBUSOutput Wiring – Intrinsically Safe
Figure 6-13 Output voltage vs. load resistance – Terminals 3 & 4 (Channel B) – Internal power
Figure 6-14 Output voltage vs. load resistance – Terminals 5 & 6 (Channel C) – Internal power
Maximum output voltage = 15 VDC ± 3%
0 500 1000 1500 2000 2500
Load resistance (Ohms)
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
High level output voltage (Volts)
Maximum output voltage = 15 VDC ± 3%
0 1000 2000 3000 4000 5000
Load resistance (Ohms)
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0