2-27
DVS 304 • Installation and Operation
f). Click Take button to tie the DVS 304’s input to the selected switcher
output. The program will create a custom script that will then be loaded
onto the DVS 304. The Status box updates with the status of the script on
the DVS 304, showing if the DVS 304’s script is connected to the matrix
switcher, and showing the current tie associated with output selected.
Using the DVS and matrix switcher after the DVS is
synchronized to the matrix switcher.
After completing step 4, above, ensure the following is done when using the DVS
with the matrix:
• Performallinputswitchingusingthematrixswitcher.A1-secondRGB
delay on the matrix is recommended to minimize the appearance of a
glitch in the output while the DVS locks onto the new signal.
• TheDVSsenseswhenthematrixswitcherchangesinputtiesand
recalls the matching input preset, so Input presets need not be recalled
manually.
• TheDVS304andthematrixswitchermustremainonthesamesubnet.
Do not change the matrix switcher’s IP address. If the IP address of the
matrix is altered, repeat step 4 above.