3 - 23
3. SIGNALS AND WIRING
3.9 Servo amplifier terminal block (TE2) wiring method
(1) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is. (Cable size: 0.2 to
2.5mm
2
)
Approx. 10mm
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to
avoid a short caused by the loose wires of the core and the adjacent pole. Do not solder
the core as it may cause a contact fault. (Cable size: 0.2 to 2.5mm
2
)Alternatively, a bar
terminal may be used to put the wires together.(Phoenix contact)
Bar terminal for 1 cable
(Bar terminal ferrule with insulation sleeve)
Bar terminal for 2 cable
(Twin ferrule with insulation sleeve)
Cable size Bar terminal type
[mm
2
] AWG For 1 cable For 2 cables
Crimping
tool
0.25 24
Al0.25-6YE
Al0.25-8YE
0.5 20
Al0.5-6WH
Al0.5-8WH
0.75 18
Al0.75-6GY
Al0.75-8GY
Al-TWIN2
0.75-8GY
Al-TWIN2
0.75-10GY
118
Al1-6RD
Al1-8RD
Al-TWIN2
1-8RD
Al-TWIN2
1-10RD
1.5 16
Al1.5-6BK
Al1.5-8BK
Al-TWIN2
1.5-8BK
Al-TWIN2
1.5-12BK
2.5 14
Al2.5-8BU
Al2.5-8BU-1000
Al-TWIN2
2.5-10BU
Al-TWIN2
2.5-13BU
CRIMPFOX-UD6