12 - 35
12. OPTIONS AND AUXILIARY EQUIPMENT
12.2.8 EMC filter
For compliance with the EMC directive of the EN standard, it is recommended to use the following filter:
(1) Combination with the servo amplifier
Recommended filter
Servo amplifier
Model Leakage current [mA]
Weight [kg]
MR-J2S-10B to MR-J2S-100B
MR-J2S-10B1 to MR-J2S-40B1
SF1252 38 0.75
MR-J2S-200B MR-J2S-350B SF1253 57 1.37
MR-J2S-500B (Note) HF3040A-TM 1.5 5.5
MR-J2S-700B (Note) HF3050A-TM 1.5 6.7
Note: Soshin Electric
(2) Connection example
NFB
L
1
L
2
L
3
L
11
L
21
L
1
L
2
L
3
LINE LOAD
3-phase
200 to 230V AC,
1-phase
230VAC or
1-phase
100 to120VAC
EMC filter Servo amplifier
(Note 1) Power supply
(Note 2)
Note: 1. For 1-phase 230VAC power supply, connect the power supply
to L
1
,L
2
and leave L
3
open.There is no L
3
for 1-phase 100 to 120VAC
power supply.
2. Connect when the power supply has earth.
L
1
L
2
L
3
(3) Outline drawing
23.0(0.906)
LABEL
LINELOAD
168.0(6.614)
L1'
L2'
L3'
L1
L2
L3
149.5(5.886)
LINE
(input side)
LOAD
(output side)
140.0(5.512)
156.0(6.142)
16.0(0.63)
42.0
8.5
SF1252
LABEL
LINELOAD
168.0(6.614)
L1'
L2'
L3'
L1
L2
L3
209.5(8.248)
LINE
(input side)
LOAD
(output side)
140.0(5.512)
156.0(6.142)
49.0
8.5
SF1253
[Unit: mm(in)]
(0.335)
(1.654)
(0.335)
(1.929)
6.0(0.236)
6.0(0.236)