Bose MR-J2S- B Stereo Amplifier User Manual


 
9 - 4
9. TROUBLESHOOTING
Display Name Definition Cause Action
1. Small acceleration/deceleration
time constant caused overshoot to
be large.
Increase acceleration/deceleration time
constant.
2. Servo system is instable to cause
overshoot.
1. Reset servo gain to proper value.
2. If servo gain cannot be set to proper
value:
1) Reduce load inertia moment ratio; or
2) Reexamine acceleration/
deceleration time constant.
31 Overspeed Speed has exceeded
the instantaneous
permissible speed.
3. Encoder faulty. Change the servo motor.
1. Short occurred in servo amplifier
output phases U, V and W.
Correct the wiring.
2. Transistor of the servo amplifier
faulty.
Checking method
Alarm (32) occurs if power is
switched on after U,V and W
are disconnected.
Change the servo amplifier.
3. Ground fault occurred in servo
amplifier output phases U, V and
W.
Correct the wiring.
32 Overcurrent Current that flew is
higher than the
permissible current
of the servo
amplifier.
4. External noise caused the
overcurrent detection circuit to
misoperate.
Take noise suppression measures.
1. Regenerative brake option is not
used.
Use the regenerative brake option.
2. Though the regenerative brake
option is used, the parameter No.
2 setting is "
00 (not used)".
Make correct setting.
3. Lead of built-in regenerative brake
resistor or regenerative brake
option is open or disconnected.
1. Change lead.
2. Connect correctly.
4. Regenerative transistor faulty. Change servo amplifier
5. Wire breakage of built-in
regenerative brake resistor or
regenerative brake option
1. For wire breakage of built-in
regenerative brake resistor, change
servo amplifier.
2. For wire breakage of regenerative brake
option, change regenerative brake
option.
33 Overvoltage Converter bus
voltage exceeded
400V.
6. Power supply voltage high. Review the power supply.
1. Bus cable disconnected. Connect correctly.
2. Bus cable fault Change the cable.
3. Noise entere bus cable. Take measures against noise.
4. Termination connector
disconnected.
Connect termination connector.
34 CRC error Bus cable is faulty
5. The same No. exists in the servo
amplifier side axis setting.
Set correctly.