3 - 9
3. SIGNALS AND WIRING
(b) Lamp load
24VDC
VDD
COM
R
Servo amplifier
MBR
SG
(3) Encoder pulse output DO-2
(Differential line driver system)
1) Interface
Max. output current: 35mA
LA
(LB, LZ)
LAR
(LBR, LZR)
LG
SD
LA
(LB, LZ)
LAR
(LBR, LZR)
SD
Servo amplifier Servo amplifier
Am26LS32 or equivalent High-speed photocoupler
150
100
2) Output pulse
Servo motor CCW rotation
LA
LAR
LB
LBR
LZ
LZR
T
/2
400 s or more
OP
LZ signal varies 3/8T on its leading edge.