Polycom C16 Speaker System User Manual


 
TroubleShooting
10 - 17
OBAM Troubleshooting
There are status LEDs associated with both the OBAM input and output con-
nections. These LEDs are positioned on either side of the OBAM link
connections as shown in the following figure. The OBAM Input LED will illu-
minate when there is a valid OBAM out connection plugged into the OBAM in
connection on this device. The OBAM Output LED will illuminate when the
OBAM out connection is plugged into a valid OBAM input port on a different
device.
In a multi-SoundStructure device system, if the OBAM LEDs are not illumi-
nated, check that the cables are properly seated into the OBAM in and out
connectors. If the cables are properly seated, try looping a known good cable
into the OBAM in and out ports as shown in the following figure. If the Sound-
Structure device’s OBAM interface is working properly the LEDs should
illuminate.
PIN 2: TXD
PIN 3: RXD
PIN 5: GROUND
PIN 7: CTS
PIN 8: RTS
C-LINK2
OBAM IR
RS-232
REMOTE CONTROL 2
REMOTE CONTROL 1
IN OUT
12V
OBAM IIN OUT
LINK2
OBAM IR
IN OUT
12V