Setting the EMG Aux Mute
To activate the mute function, use a terminal
jumper to connect the "+24 V BIAS“ terminal
(17) and the "EMG CNT“ terminal. With the
jumper in place, the auxiliary inputs will be
muted when a page is received. To deactivate
the muting function, connect the EMG termi-
nal to the "EMG GND" terminal as shown
in the diagram at right.
Setting the Emergency Mute Function
The Emergency Mute Function (EMG) (17) allows selection of
whether or not the audio level of the auxiliary inputs (11) is muted when a
page is received from the PA system.
notes
The AUX mute for the PA input terminal operates independently from the
teacher voice mute settings.
(Continue to next page)
(11) Input terminal
(17) EMG input
terminal
17 11
Jumper
17