21
Operating Controls
RC-07 Infrared Receiver
(9) DC power terminal
The AC adapter provided supplies 24 V DC power.
(10) Sensor input terminal
Connection via F-connector and coaxial cable for the infrared sensors.
It also supplies power to the sensors (24 V).
(11)AUX input terminal
Connections for TV/DVD, CD, COMPUTER, and MP3 etc.
(12) Mixing output terminal
Provides selectable line level or microphone level signal for input into external
amplifier. Output provides mixed signal from both infrared microphone and auxiliary
input.
(13) Output Level Selection
Allows selection of either line level or microphone level output
(A) Ground screw [SIGNAL GND]
(B) Mount for cable clamp - Used to bundle cables and speaker wires with tie-wraps.
10
11 12 13
9
A
B