Revox M10 Speaker System User Manual


 
M10 Re:system
12
On/Off switch
The M10 can be completely
separated from the mains supply
with the on/off switch. This is
recommended if the Revox
Multiroom System is not going to
be used for a few weeks during a
vacation, for example.
The M10 must remain switched
on during normal operation so
that access to the Multiroom
System from the connected
rooms is available at all times.
Mains connection with fuse
The M10 power connection is
adapted to the corresponding
voltage of the country of purchase
when it is delivered. Nevertheless,
we recommend that you compare
the operating voltage shown on the
rating plate with the local supply
before starting the unit up.
Fuse:
A faulty fuse may only be replaced
with one with the following values:
1.6 A, slow-acting at 100 - 120 V~
0.8 A, slow-acting at 200 - 240 V~
Note:
The M10 mains supply is fitted with
a non-grounded rubber connector.
For this reason, only the supplied
mains cable may be used.
Power LED
There is an operational display
LED both on the front and the
back of the M10 and gives an
indication of the operational state
of the M10.
The following states are shown:
LED blue
The M10 is connected to the
mains through the on/off switch
and is in standby mode.
There are no faults present.
LED green
One or more Multiroom rooms are
active.
There are no faults in the software
or hardware present.
Error LED red
There is an error display LED
both on the front and the back of
the M10 and gives an indication
of any operational faults at the
M10.
The following states are shown:
LED red - off
There are no faults in the software
or hardware present.
LED red – flashing slowly
A first generation module has been
installed in slot A1 or A2. Only
second generation modules
are
allowed in these slots.
Description: M10 Connection panel