Quick Installation Guide
29
March 2013
I2
1
Intrinsically safe:
4-20 mA/HART model:
Ex ia IIC T4 Ga
Ex ta IIIC T79 °C
-50 °C <
T
a
< +70 °C
U
i
: 30 V, I
i
: 130 mA, P
i
: 1.0 W, L
i
: 0 μH, C
i
: 7.26 nF
F
OUNDATION fieldbus model:
Ex ia IIC T4 Ga
Ex ta IIIC T69 °C
-50 °C <
T
a
< +60 °C
U
i
: 30 V, I
i
: 300 mA, P
i
: 1.5 W, L
i
: 0 μH, C
i
: 4.95 nF
Installation Drawing: 9240030-938
IB
1
FISCO model:
FISCO Field Device
Ex ia IIC T4 Ga
Ex ia/ib IIC T4 Ga/Gb
Ex ta IIIC T69 °C
-50 °C <
T
a
< +60 °C
U
i
: 17.5 V, I
i
: 380 mA, P
i
: 5.32 W, L
i
: <1 μH, C
i
: 4.95 nF
Installation Drawing: 9240030-938
Chinese certifications
National Supervision and Inspection Center for Explosion
Protection
and Safety of Instrumentation (NEPSI) approvals
Special conditions for safe use (X):
Refer to Certificates GYJ 111230X and GYJ 081131X.
E3
1
Flameproof:
HART model:
Ex d ia IIC T4 (-40 °C < T
a
< +70 °C) DIP A20 T
A
79 °C
F
OUNDATION fieldbus model:
Ex d ia IIC T4 (-40 °C < T
a
< +60 °C) DIP A20 T
A
69 °C
Approval valid for HART, F
OUNDATION fieldbus, and Modbus options.
I3
1
Intrinsically safe:
HART model:
Ex ia IIC T4 (-50 °C < T
a
< +70 °C) DIP A20 T
A
79 °C
4-20 mA/HART model: U
i
= 30 V, I
i
= 130 mA, P
i
= 1.0 W, C
i
= 7.26 nF, L
i
0 μH
F
OUNDATION fieldbus model:
Ex ia IIC T4 (-50 °C < T
a
< +60 °C) DIP A20 T
A
69 °C
U
i
= 30 V, I
i
= 300 mA, P
i
= 1.5 W, C
i
4.95nF, L
i
0 μH
Approval valid for HART and F
OUNDATION fieldbus options.
1) Ordering information code for Product Certifications, see the Rosemount 5300 Series Product Data Sheet
(Document No. 00813-0100-4530) or the Rosemount 5300 Series Reference Manual
(Document No. 00809-0100-4530).