Emerson 00825-0100-4530 Rev EC Satellite Radio User Manual


 
March 2013
26
Quick Installation Guide
I5, IE
1
Intrinsically safe and FISCO model:
Intrinsically Safe for Class I, II, III, Div. 1, Groups A, B, C, D, E, F, and G,
Class I, Zone 0, AEx ia IIC T4 when installed per Control Drawing: 9240 030-936.
Non-Incendive Class I, Div. 2, Groups A, B, C, D, F, and G;
Suitable for Class II, III, Div. 2, Groups F and G;
4-20 mA/HART model: U
i
= 30 Vdc, I
i
= 130 mA, P
i
= 1.0 W, C
i
= 7.26 nF, L
i
= 0 H.
Max. operation: 42.4 V, 25 mA
F
OUNDATION fieldbus model: U
i
= 30 Vdc, I
i
= 300 mA, P
i
= 1.3 W, C
i
= 0 nF, L
i
= 0 H.
Max. operation: 32 V, 25 mA
FISCO model: U
i
= 17.5 Vdc, I
i
= 380 mA, P
i
= 5.32 W, L
i
= C
i
= 0.
Temp. Code T4
Ambient temperature limits: -50 °C to +70 °C
2
Approval valid for HART, FOUNDATION fieldbus, and FISCO options.
Canadian Standards Association (CSA) approvals
Certificate: 1514653
Product options bearing the Dual Seal marking meets the Dual Seal Requirements of
ANSI/ISA12.27.01-2003.
Dual seal annunciation
The breach of the secondary seal is annunciated via product leakage from the antenna’s
vents. The leakage will be visible and/or audible from the transmitter
head’s threads.
Dual seal maintenance
No maintenance required. Verify proper operation by keeping leak path free from ice or
contamination.
WARNING: The substitution of components may impair intrinsic safety.
E6
1
Explosion-proof with internal intrinsically safe circuits [Exia]
Class I, Div. 1, Groups B, C, and D;
Class II, Div. 1 and 2, Groups E, F, and G;
Class III, Div. 1
Temp Code T4.
Ambient temperature limits -50 °C to +70 °C
2
Approval valid for HART, FOUNDATION fieldbus, and Modbus options.
I6, IF
1
Intrinsically Safe Exia:
Class I, Div. 1, Groups A, B, C, and D.
Temp Code T4.
4-20 mA/HART model: U
i
= 30 Vdc, I
i
= 130 mA, P
i
= 1.0 W, C
i
= 7.26 nF, L
i
= 0 H.
F
OUNDATION fieldbus model: U
i
= 30 Vdc, I
i
= 300 mA, P
i
= 1.3 W, C
i
= 0 nF, L
i
= 0 H.
FISCO model: U
i
= 17.5 Vdc, I
i
= 380 mA, P
i
= 5.32 W, L
i
= C
i
= 0.
Installation Drawing: 9240 030-937
Ambient temperature limits -50 °C to +70 °C
2
.
Approval valid for HART, F
OUNDATION fieldbus, and FISCO options.
1) Ordering information code for Product Certifications, see the Rosemount 5300 Series Product Data Sheet
(Document No. 00813-0100-4530) or the Rosemount 5300 Series Reference Manual
(Document No. 00809-0100-4530).
2) +60 °C with F
OUNDATION fieldbus or FISCO option.