Dynacord H 2500 Stereo Amplifier User Manual


 
PowerH SERIES
36 Owner’s Manual
the digital audio input offers a dynamic range of 128 dB. Using the analog audio input offers a dynamic
range of 120 dB, which, by the way, is an absolute peak value for digital audio devices.
For further details about configuration, control and monitoring of amps with installed RCM-26 modules,
please refer to the documentation of the IRIS-Net™ software.
Installation Notes
1. Switch the power amp’s power off and pull the mains plug
2. Remove the cover panel from the rear panel (4 screws)
3. Insert the RCM-26 module in the slot and lock it in place on the rear panel using the 4 screws (see
illustration 4.1)
4. Set the module’s CAN-address using the ADDRESS selector switches
5. Connect the needed interfaces (CAN, Audio, Control Port, RS-232)
6. Reconnect the mains cord and switch on the power amplifier
7. The power amp automatically recognizes the installed RCM-26 module
IRIS-Net
Configuring and controlling a remote amplifier
with a RCM-26 module installed is possible
through the use of IRIS-Net™ (Intelligent
Remote & Integrated Supervision) PC-software.
IRIS-Net™ allows programming the RCM-26
module’s complete configuration while the
computer is off-line. All instructions on how to
configure, operate and monitor all RCM-26
functions are included in the IRIS-Net™ help
files.
Illustration 4.1: Installation of a RCM-26
Illustration 4.2: DSP flow diagram of the RCM-26