Edit Mode - Navigate Macros
Press the Front Panel Prev or Next Buttons and observe the LED’s to navigate Source ON and OFF Macros as
follows:
Figure 10 Front Panel Navigation – Edit Mode (Navigating Macros)
SEQUENCE In Normal Operating Mode, press for 2 seconds (Indicated by the first blink of the Active Source
LED) to enter Edit Mode. This will allow navigation of Source ON and OFF Macros. The Source 1
and Program LED’s will illuminate solid green, by default, to indicate Edit Mode, Source 1 ON
Macro selected. Source 1 LED green and Program LED orange indicates Source 1 OFF Macro
selected. Source 2 LED green and Program LED green indicates Source 2 ON Macro selected.
Source 2 LED green and Program LED orange indicates Source 2 OFF Macro selected, etc.
PREV In Edit Mode a quick 1 second press will Navigate to the previous Command Structure. A press
of 2 seconds (Indicated by the first blink of the Active Source LED) will navigate to the previous
ON or OFF Macro. Wait for the Source LED of the newly selected Command Structure or Macro
to flash once before pressing any more buttons. To exit Edit Mode and enter into Normal Mode
press the PREV button for 5 seconds (Indicated by the second blink of the Active Source LED) or
cycle power off and on.
NEXT In Edit Mode a quick 1 second press will navigate to the next Command Structure. A press of 2
seconds (Indicated by the first blink of the Active Source LED) will navigate to the next ON or OFF
Macro. Wait for the Source LED of the newly selected Macro to
flash once before pressing any
more buttons.
TEST In Edit Mode press to Test the selected Source ON or OFF Macro. Emitters must be connected
to the ISM4 and appropriate Sources to test Macros.
DELETE In Edit Mode, a quick 1 second press will delete the current Command Structure. A 2 second
press (Indicated by the first blink of the Active Source LED), will delete the current Macro. A press
of 5 seconds (Indicated by the second blink of the Active Source LED) will delete the entire Macro
Table (all Macros).