Worth Data 7000 Stereo System User Manual


 
Other Bar Code Options
Storage Tek Label ON OFF 2
Labelcode 5 ON OFF 3
Labelcode 4 ON OFF 4
Bar Code ID's ON OFF 5
The Storage Tek Tape Label code is a proprietary variation of Code 39 code used for the storage of
computer data tapes. Enabling the tape label code does not disable reading of Code 128 or Code 39 bar
codes.
Labelcode 5 and Labelcode 4 are proprietary bar code types used by Follet.
Bar Code ID’s are characters assigned to each bar code type to identify that particular type of code.
These Bar Code IDs can output as prefix to the bar code data to identify what type of bar code you are
using. The Bar Code ID’s are assigned as follows:
Bar Code ID Bar Code ID Bar Code ID Bar Code ID
Codabar a 2 of 5 f UPC-E (1) o LabelCode 4 y
Code 39 b Code 128 g EAN-8 p LabelCode 5 z
UPC-A c Code 93 i RSS-14 r
EAN-13 d MSI j StorageTek s
I 2of 5 e UPC-E(0) n Plessey x
The ID character is transmitted in front of the bar code data.
RS-232 I/O Settings
Baud Rate
Use the 1 key to select the baud rate. The default value is 9600. The available baud rates are 2400, 4800, 9600,
19200, 38400, 57600 and 115200.
Parity
Use the 2 key to select the parity.
The options are None, Even or Odd.
None is generally used with 8 data bits
Even or Odd parity is generally used with 7 data bits.
Data Bits
Use the 3 key to select either 8 or 7 data bits.
XON / XOFF Printer
Setting 4 pertains to use of a serial Printer with your RF Terminal. Use key 4 to enable XON / XOFF if