the bar code data to the computer.
2 of 5 is so susceptible to misreads that the RF Terminal adds an additional safeguard - it can be
configured to look for fixed-length data only.
The default setting of 06 causes the RF Terminal to read only 2 of 5 codes that are 6 digits in length. To
set the RF Terminal to read a different length, enter any two-digit number. 2 of 5 code must always be
an even number of digits so the length setting must always be an even number.
Reading variable length I 2of5 or 2 of 5 codes is to be avoided if at all possible. The 00 setting is
supplied for the purposes of reading codes of unknown length, counting the digits and setting the length
to the proper number.
MSI and Plessey
MSI/Plessy ON OFF 1
MSI/Plessy-Single Mod 10 Check Digit ON OFF 1
MSI/Plessy-Double Mod 10 Check Digit ON OFF 1
MSI/Plessy-Single Mod 11/Single Mod 10 Check ON OFF 1
Enable Plessy / Disable MSI ON OFF 1
Transmit Check Digits 0, 1 or 2 2
The MSI/Plessy options are selected by pressing the 1 key to select the desired mode of operation.
If you have enabled the Mod 10 or Mod 11 check digits, they will be transmitted along with your bar
code data from the RF Terminal to your host.
For more information regarding MSI or Plessey Code, see Appendix K; MSI Plessey Code.
Code 93 / Code 11
Code 93 ON OFF 1
Code 93 Full ASCII ON OFF 2
Code 11 ON OFF 3
Code 11 Check Digit Transmission 0, 1 or 2 4
Code 93 is similar in character set to Code 39. See Appendix F; Code 93 for more information. Code 93 is
not a commonly used bar code symbology.
DataBar / RSS-14 Options
DataBar / RSS-14 ON OFF 1
DataBar / RSS-14 plus Identifiers ON OFF 1
DataBar / RSS-14 plus UCC-128 Format ON OFF 1
By default, DataBar / RSS-14 is disabled. Press the 1 key to toggle through the DataBar / RSS-14 options
listed above. We support the standard and stacked version of DataBar / RSS-14.
For more information on GS1 DataBar, see the GS1.org website at
http://www.gs1.org/productssolutions/barcodes/databar/