31
HCD-PX333
MC COLD RESET
• The cold reset clears all data including preset data stored in the RAM to initial conditions. Execute this mode when returning the set to
the customer.
Procedure:
1. Press the ?/1 button to turn the power on.
2. Press three buttons of [VOLUME ] , [REC MODE], and x (MD) simultaneously.
3. The set is reset, and displays “See you”, then becomes standby status.
AMP TEST
Procedure:
1. Press the ?/1 button to turn the power on.
2. Press three buttons of .m TUNING – , M > TUNING + ,and M > (MD) simultaneously.
3. Each buttons are pressed, it changes display as follows.
Button Display
x (CD) 7[TESTMIN]
REC MODE 8[TESTMID]
x (MD) 9[TESTMAX]
4. Press the
[VOLUME +] button, the display switches “VOLUME 21” to “VOLUME MAX”. And the display returns to the original
display after a few second.
5. Press the [VOLUME
-
] button, the display switches “VOLUME 21” to “VOLUME MIN”. And the display returns to the original
display after a few second.
6. To release from this mode, press the ?/1 button to turn the power off and cold reset.
VERSION DISPLAY
Procedure:
1. Press the
?/1 button to turn the power on.
2. Press three buttons of .m TUNING – , M > TUNING + , and [TUNER/BAND] simultaneously.
3. Enter the version display mode and STR version is shown in the upper position, the distination is shown in the lower position
4. Each time the x (MD) button is pressed, it changes display STR version → CD version → MD version → STR version → ...
5. To release from this mode, press the ?/1 button to turn the power off.
LCD AND LED TEST
Procedure:
1. Press the ?/1 button to turn the power on.
2. Press three buttons of .m TUNING – , M > TUNING + , and x (MD) simultaneously.
3. Liquid crystal display and LEDs are all turned on.
4. Each time the x (MD) button is pressed, it changes display all turned on → all turned off → pattern 1 → pattern 2 → all turned on → ...
5. Each time the x (CD) button is pressed, it changes LED indication all turned on → all turned off → “?/1” → “REC” → “N” (MD)
→ “X” (MD) → “N” (CD) → “X” (CD) → all turned on → ...
6. To release from this mode, press the ?/1 button to turn the power off.
–
SECTION 4
TEST MODE
Note 1:About “R”
As this unit has only a few buttons, some operations require the use of remote commander (RM-S55EN/provided with unit: 1-476-664-21)
buttons. These operations are indicated as “R” in this manual.
Example: MENU/NO “R” ...Press the [MENU/NO] button of the remote commander.
Note 2:Incorrect operations may be performed if the MD test mode is not entered properly.
In this case, press the ?/1 button to turn the power off, and retry to enter the MD test mode.
KEY TEST
Procedure:
1. Press the ?/1 button to turn the power on.
2. Press three buttons of .m TUNING – , M > TUNING + , and .m (MD) simultaneously.
3. Enter the key test mode and display “KEY00”.
4. Each time a button is pressed, “KEY” value increases. However, once a button is pressed, it is no longer taken into account.
5. To release from this mode, press three buttons in the same manner as step 2 , or disconnect the power cord.
PATTERN 1 PATTERN 2
CD
DBFB
OVER
TRACK
TOC
SYNC ITHCMS 2 MONO
PRESET
SHUFFLE
c
DAILY
c
REC 2
1
MD
OVER
DISC
TEXT
S.F EDIT NORM
REC L-SYNCHIGH
LP 4
MONOTUNED
MANUAL AUTO
PROGRAM REPEAT
1 3
SLEEP