Technical Information
ENGLISH - 95
Appendix
PJLink protocol
The network function of this projector supports the PJLink class 1, and the PJLink protocol can be used to
perform projector setting and projector status query operations from a computer.
■ Control commands
The following table lists the PJLink protocol commands that can be used to control the projector.
Command Control details Notes
POWR Power supply control
Parameters
0 = Standby
1 = Power ON
POWR? Power supply status query
Parameters
0 = Standby 1 = Power ON
2 = Cool-down in progress 3 = Warm-up in progress
INPT Input selection
Parameters
11=RGB1 12=RGB2 21=VIDEO
22=S-VIDEO 31=DVI-D
INPT? Input selection query
AVMT Shutter control Parameters
30 = SHUTTER function off (picture mute canceled)
31 = SHUTTER function on (picture mute)
AV
MT? Shutter status query
ERST? Error status query
Parameters
1st byte: Indicates fan errors, range 0 - 2
2nd byte: Indicates lamp errors, range 0 - 2
3rd byte: Indicates temperature errors, range 0 - 2
4th byte: Indicates cover open errors, range 0 - 2
5th byte: Indicates lter errors, range 0 - 2
6th byte: Indicates other errors, range 0 - 2
Denitions for each value from 0 to 2 are as follows
0 = No error detected 1 = Wa
rning 2 = Error
LAMP? Lamp status query
Parameters
1st digits (1 - 5 digits): Lamp 1 cumulative operating time
2nd digit: 0 = Lamp 1 off, 1 = Lamp 1 on
3rd digits (1 - 5 digits): Lamp 2 cumulative operating time
4th digit: 0 = Lamp 2 off, 1 = Lamp 2 on
INST? Input selection list query
Parameters are returned with the following values.
“
11 12 21 22 31
”
NAME? Projector name query
R
eturns the name set in [PROJECTOR NAME] of [NETWORK
SETUP].
INF1? Manufacturer name query Returns
“
Panasonic
”
.
INF2? Model name query Returns
“
DX800U
”
“
DW730U
”
.
INF0? Other information query Returns information such as version number.
CLSS? Class information query Returns
“
1
”
.
■ PJLink security authentication
The password used for PJLink is the same as that of the password set for web browser control.
When using PJLink without security authentication, do not set a password for web browser control.
z
For specications regarding PJLink, refer to the Japan Business Machine and Information System
Industries Association website.
URL http://pjlink.jbmia.or.jp/english/