Panasonic PT-DX800U Home Theater System User Manual


 
[PROJECTOR SETUP] menu
64 - ENGLISH
Settings
[REMOTE2 MODE]
You can set the <REMOTE 2 IN> terminal.
1) Press
▲▼
to select [REMOTE2 MODE].
2) Press ◀▶ to switch [REMOTE2
MODE].
z
The setting will change as follows each time
you press the button.
[DEFAULT] [USER]
[DEFAULT]
The pin assignment of the
<REMOTE 2 IN> terminal is used
by the factory default setting of the
projector.
(
page 100)
[USER]
Used to change the setting of the
<REMOTE 2 IN> terminal.
When selecting [USER] in Step 2)
3) Press the <ENTER> button.
4) Press
▲▼
to select an item from
[PIN2] to [PIN8], and press ◀▶ to
switch the setting.
[STATUS]
Displays the status of the projector.
1) Press
▲▼
to select [STATUS].
2) Press the <ENTER> button.
3) Press ◀▶ to switch the pages.
[INPUT]
Displays the input terminal currently
selected.
[NAME] Displays the input signal name.
[SIGNAL
FREQUENCY]
Displays the frequency of the input
signal.
[PROJECTOR
RUNTIME]
Displays the operation hours of the
projector.
[LAMP1]
*1
Displays the lighting time of the lamp 1.
[LAMP2]
*1
Displays the lighting time of the lamp 2.
[INTAKE AIR
TEMP.]
Displays the status of the air intake
temperature of the projector.
[OPTICS
MODULE TEMP.]
Displays the status of the internal
temperature of the projector.
[AROUND
LAMP TEMP.]
Displays the status of the
temperature around the lamps of
the projector.
[PROJECTOR
TYPE]
Displays the type of the projector.
[SERIAL
NUMBER]
Displays the serial number of the
projector.
[LAMP UNIT
MODEL NO.]
Displays the model no. of the lamp
unit.
[LAMP1 SERIAL
NUMBER]
Displays the serial number of the
lamp 1.
[LAMP2 SERIAL
NUMBER]
Displays the serial number of the
lamp 2.
[MAIN
VERSION]
Displays the main version of the
rmware of the projector.
[SUB VERSION]
Displays the sub version of the
rmware of the projector.
[NETWORK
VERSION]
Displays the network version of the
projector.
[ON COUNT]
z
[POWER ON TIMES]:
Displays the number of times the
pow
er is turned on.
z
[
LAMP1 ON]:
Displays the number of times the
lamp 1 is turned on.
z
[LAMP2 ON]:
Displays the number of times the
lamp 2 is turned on.
z
[SHUTTER]:
Displays the number of times the
shutter function is used.
[LAMP1]
Displays the details of the usage time.
[LAMP2]
Displays the details of the usage time.
[NUMBER OF
ENTRY SIGNAL]
Displays the number of registered
signals.
[REMOTE2
STATUS]
D
isplays the control status of the
REMOTE2.
*1: The lamp lighting time displayed is actual time.
The following conversion is required to calculate the
guideline for lamp replacement.
Time to replace the lamp =
The usage time when [LAMP POWER] is
set to [HIGH] +
(the usage time when [LAMP POWER] is
set to [LOW] x 2
÷
3)
Note
z
The contents of the status can be sent via E-mail
when the <ENTER> button is pressed while the
status is displayed.