Intel SBFCM Stereo Receiver User Manual


 
149
Switch diagnostic information
The following LED error codes, I2C diagnostic register definitions, and alarms support the Fibre Channel
Switch Module.
LED error codes
I2C diagnostic register definitions
NOTE
See Chapter 6, “SBCEFCSW / SBFCM Parts listing,” on page 153 to determine which components
should be replaced by a field service technician.
Heartbeat LED error codes Action
2 blinks Internal application failure (switch is inoperable, reset is required)
3 blinks Fatal POST error (switch is inoperable)
4 blinks Corrupt flash or configuration ("config restore" required to clear
fault condition)
NOTE
See Chapter 6, “SBCEFCSW / SBFCM Parts listing,” on page 153 to determine which components
should be replaced by a field service technician.
Port LED error codes Action
Fast blink Port is inoperable (either hardware problem detected by POST,
E_Port isolated, or user set the port to "down" state)
NOTE
See Chapter 6, “SBCEFCSW / SBFCM Parts listing,” on page 153 to determine which components
should be replaced by a field service technician.
Progress indicators Action
0x01 - Initialization N/A
0x10 - Serial PROM test N/A
0x20 - ASIC Register test N/A
0x40 - Loopback test group 1 N/A
0x50 - Loopback test group 2 N/A
0x60 - Loopback test group 3 N/A
0x70 - Creating test results summary
(determining compromised vs. failed)
N/A
0xff - POST complete N/A