Getting Started Connections Other Operations Multi-Zone Information Troubleshooting SpecificationsSetup
ENTER
ui
STEP3 Measurement (2nd – 8th)
• In STEP 3, you will perform measurements at multiple positions
(two to eight positions) other than the main listening position.
Measurements can be made in up to eight positions.
• You can achieve a more effective correction of distortion within the
listening area by performing measurements at multiple positions.
• Move the provided set up microphone to the measurement point.
1
Move the setup microphone to position 2, use ui to
select “Measure”, and then press ENTER.
The measurement of the second position starts.
AUTO SETUP
1 2 3 4 5 6
Measure
RETURN
Next→Calculation
STEP3 Measurement (2nd)
Please place the microphone at ear
height at 2nd listening position.
Start measurement. Output large test tone during measuring
Enter Cancel
b To omit measurements from the 2nd position onwards, press i,
select “Next Calculation” and press
ENTER
. Proceed to “STEP4
Calculation”.
2
Repeat step 1, measuring positions 3 to 8.
When measurement of position 8 is completed, a “Measurements
finished.” message is displayed.
b To re-measure, press i to select “Retry”, and press ENTER. Re-
measure the previous point.
AUTO SETUP
1 2 3 4 5 6
Retry
RETURN
Next→Calculation
STEP3 Measurement (Finish)
Measurements finished.
Proceed to STEP 4 (Calculation)
Enter Cancel
3
Use i to select “Next Calculation” and then press
ENTER.
Proceed to “STEP4 Calculation” (vpage 18).
NOTE
If “Caution!” is displayed on the television screen, see “Error
messages” (vpage 21). Check the related items, and implement
the necessary measures. After resolving the error, perform Auto Setup
again.
n When measuring has stopped
Press ENTER.
STEP4 Calculation
In STEP 4, the measured results from STEP 2 and STEP 3 are analyzed.
When the measurements are completed, press i to select
“Next Calculation”, and press ENTER.
The measured results from STEP 2 and STEP 3 are automatically
analyzed, and the frequency response of each speaker in the listening
room is determined.
AUTO SETUP
1 2 3 4 5 6
STEP4 Calculation
Now calculating…Please wait.
20%
b
It takes a few minutes for analysis to complete. The time required
for this analysis depends on the number of speakers connected.
The more connected speakers there are, the longer it takes to
perform analysis.
ENTER
u
i
(Main remote control unit) (Sub remote control unit)
i
ENTER
u