A SERVICE OF

logo

Note: For more information on the 12-80V DC direct, UPS battery pack and extension cable
connections please refer to the appropriate section earlier in this manual.
How To Connect Power Adapter Cable
1. The VX6 must be turned off and the power cable must be UNPLUGGED from the VX6.
2. Attach the smaller end of the Power Adapter Cable to the VX1/2/4 power cable by aligning
the water-tight connector pins to the power cable connector. Push down on the water-tight
connector and twist it to fasten securely.
3. Connect the larger end of the Power Cable directly to the computer or to a UPS battery pack,
as desired. Please refer to the appropriate section earlier in this manual for UPS battery pack
connection details.
Fuse Replacement for the VX6
The VX6 uses a 100V, 10A time delay (slow blow), high current interrupting rating fuse that is
externally accessible and user replaceable. Should it need replacement, replace with same
size, rating and type of fuse – Littlefuse 0234010 or Optifuse MSC-10A (5x20mm).
1. Turn the VX6 off and disconnect the power cable from the VX6.
Caution:
Fuse has voltage on it even when power is off. Always disconnect
input power before changing fuse.
2. While holding the VX6 over a level surface, push the fuse cover in and twist it one quarter
turn counterclockwise. A flat head screwdriver may be used to twist the fuse cover.
3. Remove the fuse.
4. Discard the fuse and place a new fuse in the holder.
5. Push the fuse in and twist it clockwise one quarter turn.
6. Reconnect the power cable to the VX6.