Installing the VCN Access Concentrator 37
Procedures for a non-SuperStack Switch Automated procedures for
non-SuperStack switches are not available. For a non-SuperStack switch,
the Manual Procedures for SuperStack II 1100/3300
serve as a general
outline for manual MAC address insertion, but the user follows the
detailed instructions in the non-SuperStack switch user guide. Implement
the MAC addresses listed in Ta b l e 7
for the VCN AC. Repeat the
procedure to define the MAC addresses of the 24 VCN APs attached to
the VCN AC. Start with the lowest VCN AP MAC address of
00-C0-DA-40-80-19 and assign addresses for up to 24 VCN APs
consecutively.
Manual Procedures for SuperStack II 1100/3300 Enter every one of
the 24 VCN AC port MAC addresses through the SuperStack II web
management interface.
Refer to the SuperStack® II Switch Management Guide, and follow the
instructions in the section “Inserting Permanent Entries” for the Switch
Database dialog. You will need to use a web browser on the computer
connected to the switch.
Insert the VCN AC port MAC addresses before connecting the VCN AC to
the Ethernet switch.
To manually insert a MAC address for an VCN AC port:
1
From the
Port Filter
list box, select a port for the entry.
Ignore the
VLAN Filter
list box.
2
In the
Enter MAC Address
field, enter the MAC (Ethernet) address for the
port.
3
From the
Select Action Type
list box, select
Insert
.
4
Click the
Apply
button.
The Display Database Entries table displays the new entry.
5
Repeat steps 1 through 4 for every port.
The Display Database Entries table is not automatically updated with the
new entry.
To update the table:
1
From the
Select Action Type
list box, select Display All
.
2
Click the
Apply
button
.