Sony STRDN1020 Stereo System User Manual


 
41
GB
D:\NORM'S JOB\SONY HA\SO0126\STR-DN1020\4282218111_GB Web\GB04GET_STR-
DN1020-CEL.fm
masterpage: Right
STR-DN1020
4-282-218-11(1)
Preparing the Receiver
3 Press V/v repeatedly to select
“Auto Cal.”, then press or b.
4 Press B/b repeatedly to select
“Standard”, then press .
The calibration type is automatically set
to “Engineer”.
5 Press to select “START”.
6 The measurement starts in five
seconds.
The measurement process will take
approximately 30 seconds with a test
tone.
When the measurement ends, a beep
sounds and the screen switches.
Note
If an error code appears on the screen, see
“Message list after Auto Calibration
measurement” (page 42).
7 Press V/v repeatedly to select
the item you want, then press
.
Retry: Performs the Auto Calibration
again.
Save: Save the measurement results and
exits the setting process.
Warning: Displays warning related to
the measurement results. See “Message
list after Auto Calibration
measurement” (page 42).
Exit: Exits the setting process without
saving the measurement results.
8 Save the measurement result.
Select “Save” in step 7.
Notes
You can select the calibration type you want
by using the “Custom” Auto Calibration
(page 43).
The A.P.M. (Automatic Phase Matching)
function is activated after you save the
measurement result.
The A.P.M. (Automatic Phase Matching)
function does not work in the following cases.
The calibration type is set to “Off” when
using the “Custom” Auto Calibration
(page 43).
When Dolby TrueHD or DTS-HD signals
with a sampling frequency of more than
48 kHz are being received.
9 Disconnect the optimizer
microphone from the receiver.
Note
If you reposition your speaker, we recommend that
you perform Auto Calibration again to enjoy the
surround sound.
Tips
You can change the unit of distance in “Distance
Unit” in the Speaker settings menu (page 94).
The size of a speaker (“Large”/“Small”) is
determined by the low frequency characteristics.
The measurement results may vary, depending on
the position of the optimizer microphone and
speakers, and the shape of the room. It is
recommended that you apply the measurement
results. However, you can change those settings in
the Speaker Settings menu. Save the measurement
results first, then try to change the settings.
continued