4. Exclusive Communications
The GI-20 is capable of transmitting and receiving system parameters and patch parameters
using certain exclusive messages. The model ID is 00H 6AH. The Device ID is fixed as 10H.
The use of Device ID 7FH (Broadcast) is not supported.
Data Set 1 DT1 (12H)
Byte Explanation
F0H Exclusive Status
41H Manufacturer ID (Roland)
10H Device ID (Dev=10H)
00H Model ID MSB (GI-20)
6AH Model ID LSB (GI-20)
12H Command ID (DT1)
aaH Address MSB
bbH Address
ccH Address
ddH Address LSB
eeH Data
: :
ffH Data
sum Checksum
F7H EOX (End of Exclusive)
* The GI-20 can only transmit and receive bulk data, not individual data.
* Data is received only when the unit has been placed in standby, in the Bulk Load screen.
* The use of Data Request is not supported.
* Data is transmitted when [WRITE] is pressed in the Bulk Load screen.
* Does not respond to Identity Request inquiry messages.
Decimal and Hexadecimal table
With a MIDI System, the data value, the address, or size in an exclusive message is
expressed in 7-bit hexadecimal values.The table below shows decimal value and their
hexadecimal counterparts.
+——————+——————++——————+——————++——————+——————++——————+——————+
| 10 | 16 || 10 | 16 || 10 | 16 || 10 | 16 |
+——————+——————++——————+——————++——————+——————++——————+——————+
| 0 | 00H || 32 | 20H || 64 | 40H || 96 | 60H |
| 1 | 01H || 33 | 21H || 65 | 41H || 97 | 61H |
| 2 | 02H || 34 | 22H || 66 | 42H || 98 | 62H |
| 3 | 03H || 35 | 23H || 67 | 43H || 99 | 63H |
| 4 | 04H || 36 | 24H || 68 | 44H || 100 | 64H |
| 5 | 05H || 37 | 25H || 69 | 45H || 101 | 65H |
| 6 | 06H || 38 | 26H || 70 | 46H || 102 | 66H |
| 7 | 07H || 39 | 27H || 71 | 47H || 103 | 67H |
| 8 | 08H || 40 | 28H || 72 | 48H || 104 | 68H |
| 9 | 09H || 41 | 29H || 73 | 49H || 105 | 69H |
| 10 | 0AH || 42 | 2AH || 74 | 4AH || 106 | 6AH |
| 11 | 0BH || 43 | 2BH || 75 | 4BH || 107 | 6BH |
| 12 | 0CH || 44 | 2CH || 76 | 4CH || 108 | 6CH |
| 13 | 0DH || 45 | 2DH || 77 | 4DH || 109 | 6DH |
| 14 | 0EH || 46 | 2EH || 78 | 4EH || 110 | 6EH |
| 15 | 0FH || 47 | 2FH || 79 | 4FH || 111 | 6FH |
| 16 | 10H || 48 | 30H || 80 | 50H || 112 | 70H |
| 17 | 11H || 49 | 31H || 81 | 51H || 113 | 71H |
| 18 | 12H || 50 | 32H || 82 | 52H || 114 | 72H |
| 19 | 13H || 51 | 33H || 83 | 53H || 115 | 73H |
| 20 | 14H || 52 | 34H || 84 | 54H || 116 | 74H |
| 21 | 15H || 53 | 35H || 85 | 55H || 117 | 75H |
| 22 | 16H || 54 | 36H || 86 | 56H || 118 | 76H |
| 23 | 17H || 55 | 37H || 87 | 57H || 119 | 77H |
| 24 | 18H || 56 | 38H || 88 | 58H || 120 | 78H |
| 25 | 19H || 57 | 39H || 89 | 59H || 121 | 79H |
| 26 | 1AH || 58 | 3AH || 90 | 5AH || 122 | 7AH |
| 27 | 1BH || 59 | 3BH || 91 | 5BH || 123 | 7BH |
| 28 | 1CH || 60 | 3CH || 92 | 5CH || 124 | 7CH |
| 29 | 1DH || 61 | 3DH || 93 | 5DH || 125 | 7DH |
| 30 | 1EH || 62 | 3EH || 94 | 5EH || 126 | 7EH |
| 31 | 1FH || 63 | 3FH || 95 | 5FH || 127 | 7FH |
+——————+——————++——————+——————++——————+——————++——————+——————+
*When expressing a MIDI channel number or a program change number, please notice
that the values are less by one. For example, MIDI channel is expressed as 0 through 15
instead of 1 through 16.
* The range of 7 bit can express 128 steps from 0 to 127. To express broader range, use
several data bytes.