16
Set Up and Basic Operations
4.
Re-press [ENTER]. Reset will be executed. Once the reset is completed, system
go back to normal screen after indicating Completed. on screen.
Meters
Press the [METER] button to select from the three types of level meters.
Input (IN)
fig.LcdInputMeter.eps
This displays the input level. The [METER] button lights up in green.
Dynamics (CMP / EXP)
fig.LcdDynamicsMeter.eps
This displays the level suppressed by the dynamics processors (gain reduction).
The [METER] button lights up in red.
Pressing the [PAGE] buttons switches what is displayed between the
compressor and the expander.
Output (OUT)
fig.LcdOutputMeter.eps
This displays the output level. The [METER] button lights up in orange.
Edit Channel Select (EDIT CH SELECT)
These choose the channel to edit. Pressing an [EDIT CH SELECT] button makes the button light up green,
showing that the corresponding channel is selected. You make the settings for effects one channel at a time.
The system enters Link Mode pressing channel 2 button holding down channel 1 button. (Linking (p. 28))
Effect Parameter Value Effect Parameter Value
mic modeling MODEL OFF compressor COMP OFF
INPUT C3000B TYPE SOLID
OUTPUT SML.D KEYIN same channel
PROXFX 0 THRESH -24.0
TIME 0 RATIO 2.00:1
equalizer EQ ON KNEE HARD
ATT 0 ATTACK 10.0
LOW
LOTYPE PEAK RELEAS 500
LOW 80 LEVEL 0.0
GAIN 0.0 A.GAIN OFF
Q 2.00 expander EXP OFF
LO-MID
LMTYPE PEAK KEYIN same channel
LO-MID 400 THRESH -40
GAIN 0.0 RATIO 2.00:1
Q 2.00 ATTACK 0.0
HI-MID
HMTYPE PEAK RELEAS 500
HI-MID 2.00k enhancer/de-esser ENH/DE OFF
GAIN 0.0 TYPE ENH
Q 2.00
ENH
SENS 25
HIGH
HITYPE PEAK FREQ 10.0k
HIGH 10.0k ENHLEV 6,0
GAIN 0.0
DES
SENS 25
Q 2.00 FREQ 10.0k
DESREJ -6.0