Pelco C2900M-B Stereo Receiver User Manual


 
88 C2900M-B (1/03)
Connect a PV130 Converter to the RS-232 port on the front of the NET101R/R-A receiver. The
data format must be 9600 baud, 8 data bits, odd parity, and 1 stop bit.
Connect the black and white striped wire from the power supply that comes with the converter
to the converter’s +12 VDC terminal and the solid black wire to the GND terminal.
Connect TD(A) on the converter to terminal 7 on the wall block. Connect TD(B) on the converter
to terminal 8 on the wall block. Connect RD(A) on the converter to terminal 2 on the wall block.
Connect RD(B) on the converter to terminal 1 on the wall block.
Connect a 12 VAC power supply to terminals 3 and 4 on the wall block.
Connect the wall block to the KBD4000 with an RJ-45 straight cable.
Connect the monitor.
Refer to Figures 38 and 40. Splice the supplied DB9 cable into the multiplexer wall block.
Connect TX- from the NET104A to terminal 2 on the wall block, TX+ to terminal 1, RX- to
terminal 7, and RX+ to terminal 8.
Plug the supplied DB9 cable into the COM port on the transmitter. The data format must be
9600, 8, odd, 1.
Connect the wall block to COM IN on the multiplexer with an RJ-45 straight cable.
ᕫᕾ Connect MAIN video output from the multiplexer to the transmitter.