Pelco C2900M-B Stereo Receiver User Manual


 
C2900M-B (1/03) 59
Receiver email empty If applicable, enter the e-mail address where you
address want an e-mail sent in the event of an alarm.
Idle state open You can configure the switching behavior of each
built-in relay output at idle: open (N.O. at zero
current) or closed (N.C. at zero current).
Operating mode Bistable Select an operating mode for each relay.
When you select the default Bistable mode, the
relay will stay in the idle or active state for an
indefinite period. (For example, select Bistable if
a floodlight activated by an alarm is to remain
switched on at the end of the alarm.)
When you select Monostable mode, the relay
automatically falls back to the idle state after a
predefined period expires. (For example, select
Monostable 10s if a siren triggered by an alarm is
to sound for a period of 10 seconds.)
Relay follows None If necessary, select a particular event from the pull-
down menu that will trigger the relay. A typical
application is having the relay following the status of
the connection; for example, to power peripheral
equipment or even the camera itself. Select from the
following:
Motion alarm: Triggering by motion alarm
Input pin: Triggering by external alarm sensor
Video loss: Triggering by video signal alarm
Connection: Triggering at each connection setup
Remote input pin: Triggering by switching
contact of the remote station
None: No relay triggering by events
Relay Names Relay 1-4 Assign a relay name to each output.
Trigger Relay n/a Clicking the appropriate Relay button switches that
relay by hand. Typical applications are opening
remote doors or operating lights.
Table F. Alarm Settings (Continued)