OMWT-SOFT-OPC Server .ini File Format OMWT-SOFT-OPC Server
DIGCOUNTER and Directional Counter
(OMWT-IRCNT, OMWT-DIRCNT)
[Device
n
] - S
ection name.
Address
- serial number of the sensor.
D
eviceType
- Device type. (DeviceType=DIGCOUNTER or
DIRECTCNT)
PollTime
- How often to poll the device. (ms)
Label
- Name used for the device (and Topic) (typically DIGCOUNTER1
or DIRECTCNT1).
Log
- Enable/disable logging of device.
LogDecimalPlaces
- Number of decimals to create when logging.
ScaleA
- Multiplier for Counter A
ScaleB
- Multiplier for Counter B
UnitsA
- Generic label for units - no function
UnitsB
- Generic label for units - no function
DescriptionA
- Generic description field
DescriptionB
- Generic description field
EnableCounterB
- Enable the gather of Counter B
Description