Niles Audio ZR-6 Stereo Receiver User Manual


 
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-437322
OVERVIEW
Any zone of the ZR-6 MultiZone Receiver can be expanded to contain up to three keypads. This is ideal for large rooms, bedrooms, and
outdoor applications.
NILES ZR-KE KEYPAD EXPANDER
The optional Niles ZR-KE Keypad Expander (FG01494) enables the use of up to three keypads per zone. A RJ-45 terminated CAT-5 cable
from a ZR-6 MultiZone Receiver keypad port is connected to the input of the ZR-KE. The three keypads are then connected to the outputs
of the ZR-KE using CAT-5 cable. One ZR-KE can be used for each zone, including any Slave zones when multiple ZR-6 MultiZone Receivers
are used to expand the number of system zones.
KEYPAD POWER VALUE (KPV)
When a large number of keypads are used in a system, additional power may be required to power the keypads. An optional power supply
(Niles 12VDC Universal Wall Adaptor FG01035) connects to the ZR-KE to supply this additional power, if necessary. To determine if the
keypads require additional power, calculate the keypad power value (KPV) by adding the point values of all keypads connected to each
chassis.
A single ZR-6 MultiZone Receiver Chassis will supply
power up to a total KPV of 30 points. Exceeding this
KPV will compromise operation of the MultiZone
Receiver and/or keypads.
ADDING ADDITIONAL KEYPADS TO A ZONE
SYSTEM WIRING DIAGRAMS
KEYPADSVIDEO SYNC
1 2 3
5 64
2 3 4
5 6
MICROFLASHERS® 12V TRIGGERS
2 3 4
65
Global
Zone 4
EXPANSION
In
Out
AM/FM
L
R
Page
2 3 4
5 6
Audio
i Po d
®
ZONE 6ZONE 5ZONE 4ZONE 3ZONE 2ZONE 1
Zone 5
Zone 6
HT
Sync
IR In
RS232
120 Volts ~ 60Hz. 500 Watts Max.
Niles Audio Corporation
Miami, Florida USA
Double Insulated
When servicing use only
identical replacement parts.
Thi s de vi c e c om p li es w it h pa r t 1 5 of t he F CC Ru l es . O p er at io n is s ub je c t to th e fol l ow in g tw o co nd i ti on s : ( 1) Th is d ev i ce
may no t ca us e h ar m fu l i nt er f er en ce , a nd ( 2 ) th is de vi ce mu st a c ce pt any in te r fe re nc e r ec ei v ed , in c lu di n g in te r fe re n ce
tha t m ay c a us e u nd es i re d o pe ra ti o n.
CAUT ION
RISK OF EL ECTRIC SHOCK
DO N OT OPE N
AVIS
RISQ UE DE CHOC EL ECTRIQ UE
NE P AS OUV RIR
ZR-6
MultiZone Receiver
Global
32 4 5 6
AUDIO INPUTS
54 6
PREAMP OUTPUTS
8 Ω (4 Min.)
Speaker Outputs
Class 2 Wiring
8 Ω (4 Min.)
Speaker Outputs
Class 2 Wiring
8 Ω (4 Min.)
Speaker Outputs
Class 2 Wiring
8 Ω (4 Min.)
Speaker Outputs
Class 2 Wiring
8 Ω (4 Min.)
Speaker Outputs
Class 2 Wiring
8 Ω (4 Min.)
Speaker Outputs
Class 2 Wiring
VOLTAGE SYNC
INPUT 2 OR CASCADE OUT FOR iPod
SERIAL # LABEL HERE
High Output
Flasher
L+ L- R- R+L+ L- R- R+ L+ L- R- R+L+ L- R- R+ L+ L- R- R+L+ L- R- R+ L+ L- R- R+L+ L- R- R+ L+ L- R- R+L+ L- R- R+ L+ L- R- R+L+ L- R- R+
ZR-6
Solo-6 MDSolo-6 IRSolo-6 IR
ZR-KE
Keypad 1 Keypad 2 Keypad 3
Flasher
Audio
WIRING LEGEND
CAT-5
Figure 8. ZR-6 MultiZone Receiver with 3 keypads in zone
AC
(Optional)
CALCULATION TABLE
FOR KPV
ZR-6
Solo-6 IR 1 point
POWERS UP TO
A TOTAL KPV OF
30 POINTS**
NUMERIC-6P 1 point
Solo-6 MD 3 points
**Keypads connected to a ZR-KE keypad expander that utilizes
an external power supply are not included in the kpv calculation.
DS00643A-1 ZR6 Manual.indd 22 7/22/08 11:56:29 AM