Marantz PMD680 Stereo System User Manual


 
12
RECORDING
Recording Operation
Basic Procedure
Pressing REC/MARK key in stop status, the unit
enters rec-pause status.
Pressing REC/MARK key in rec-pause status, the unit
enters recording status.
Pressing PLAY/PAUSE key in recording status, the
unit enters rec-pause status.
Pressing REC/MARK key in recording status, the unit
put mark at that point (regarding mark, refer to
Marking and EDL playback on page xx).
Pressing STOP key in recording status or in rec-pause
status, the unit enters stop status.
Sound Level Monitoring
In rec-pause status and in recording status, the input
sound becomes audible (through the internal speaker or
head phone) and sound level is displayed at the level
meter.
Recording Indication
During rec-pause status, REC indicator on the display
and REC LED on the front panel blink.
During recording status, REC indicator on the display
and REC LED on the front panel turn on.
REC LED dimms when the limitter works.
(Refer to REC LEVEL on page xx)
Track Number of New Recording
Track number of new recording is next number to that
of the last track. If number of the last track is N, the
track number of new recording is N+1.
Card full
When card becomes full while recording, the recording
is stopped, the card full message "FUL Card" is
displayed for 3 seconds.
This message is also displayed when attempt to start
recording was made (REC/MARK button was pressed)
after card full. Then the unit stops.
Track Full
The maximum track number in a card is 255 tracks.
When attempt to start recording was made (REC/
MARK button was pressed) while 255 tracks exits
already in a card, track full message "FUL 255" is
displayed.
Caution
Changing REC MODE switch during recording or rec-
pause is not effective. The change is effective only in
stop status and the REC MODE is applied to the next
track recording.
The minimum length of one track is 0.5 second. A track
less than 0.5 second is not generated (If you start
recording and stop it after less 0.5 second, a track would
not be made).
record settings
STOP
REC/MARK
REC LED
REC
SP LP
-dB
50 40 24 6 2 0
TRACK
TIME
12
OVER