JBL 260 Stereo Equalizer User Manual


 
28
DriveRack
®
DriveRack® User Manual
Section 4
The DriveRack 260 offers complete editing flexibility, by offering in-depth control over every
parameter within each effect module. The following section will provide you with descriptions
and explanations of all parameters within the DriveRack 260.
4.1 Pre-Crossover EQ (28 Band Graphic or 9-Band Parametric)
The DriveRack 260’s Pre-Crossover EQ section may be configured as a single or linkable 28
band graphic EQ or 9-Band Parametric EQ.
GEQ
EQ On/Off
Turns the EQ on and off.
Flatten/Restore
This parameter either flattens the GEQ settings (sets all bands to 0 dB) or restores (think of this
as ‘undo’) the GEQ to the last settings before flattening. The DriveRack unit allows you to leave
the EQ edit window and return without losing the edited EQ settings.
Frequency (F) 31.5Hz to 16.0kHz
This parameter allows you to select any one of the 28 available frequency bands.
Gain (G) -12 to +12 dB
This parameter allows you to adjust the level of any one of the 28 bands of the GEQ in .5 dB
increments.
PEQ
EQ On/Off
Turns the PEQ on and off.
Flat Set/Undo
This parameter either flattens (sets all bands to 0 dB) or restores (think of this as ‘undo’) all
bands to their original settings.
Band 1 Frequency 20 to 20kHz (Low Shelf)
Selects the frequency of the low pass shelf parametric EQ.
Slope 1 3-12dB/Octave
Sets the slope of the low shelf parametric EQ.
Level 1 -12 to 12 dB
Sets the overall gain of the shelf EQ.
Band (2-8) Frequency 20 to 20k
Selects the frequency of the selected band of the parametric EQ.
Q (2-8) 0.20 to 16.0
Adjusts the Q of the selected band of the parametric EQ.
Level (2-8) -12 to 12 dB
Sets the overall level of the selected parametric EQ frequency.
Detailed Parameters