65
PARAMETER SETTING PRIOR TO DELIVERY
The damping value (time constant), function of zero/span adjust screw, output current mode, indicator
scale, cut point, mode below cut point and burnout, have been set prior to delivery as shown in the
following.
Note 1: For span adjustment, HHC should be used. HHC can also be used for zero adjustment.
Note 2: In both the differential pressure transmitter and remote seal type, the output current mode is
set in linear unless it is designated.
Note 3: Burnout direction is selectable from HHC, Hold, Over scale (20.8 to 21.6), under scale (3.2 to
3.8mA).
A3
ItemNo.
Damping value
(time constant)
Zero adjust
screw function
Current output mode
Digital indicator scale
(9th digit of code
symbols)
Cut point
(square-root extraction
mode setting)
Mode below cut point
(square-root setting)
Linear
Burnout
To be set by designation
when ordering ( Note 3)
1
2
3
4
5
6
To be set by designating type
when ordering
7.07%
Contents of parameter
No Damping
(= measuring period)
Zero point adjustment possible
To be set by designation
when ordering (Note 2)
7
Linearization function
Invalid