20
Indication of measured data
The measured value can be indi-
cated.
For more information about
operating procedure, refer to the in-
struction manual of HHC.
C-1: DATA
STANDBY
PUSH CL KEY
XXX. X%FLOW
C: DATA
< INC > < ENT >
XXXXXkPa
< CHANGE > < CL >
CL
CL
D-1: SELF CHECK
D-2: SELF CHECK
ALM CHECK
< 1 > AMP TEMP
D: SELF CHECK
< INC > < ENT >
< 2 > ALM CHECK
< 1 > < 2 > <CL >
< CL >
GOOD
D-2: SELF CHECK
TEMP=XXX.X °C
(YYY.Y °F)
< CL > <INC>
D-2: SELF CHECK
CELL FAULT (C1)
< CL > < INC >
D-2: SELF CHECK
TEMP=XXX.X °C
TEMP.ALARM
Temperature is displayed in °C and °F
alternately at each press of the <INC> key.
1
CL1 2
2
CL
CL
3
4
5
6
B
DATA
C-1:DATA
XXX. XX %FLOW
XXXXX kPa
< CHANGE > < CL >
CL
:
"FLOW" is displayed
when output mode is
square root extraction
mode.
:
" flicker" is displayed
when the communica-
tion between transmitter
and HHC is normal.
(HHC is not used for 10 minutes)
CHNG
INC
CHNG
ENT
INC
ENT
(Temperature alarm is displayed)
INC
CL
(Trouble in transmitter)
E: PRINT
Self-diagnosis
Use for displaying the measured
temperature in the transmitter and
the alarm information.
When pressing <1> on display 2 ,
the temperature in the amplifier
(AMP TEMP) is displayed. When
pressing <2>, result of self-
diagnosis about transmitter (ALM
CHECK) is displayed.
Result of diagnosis
When the temperature in the ampli-
fier is normal:
When temperature alarm is detected:
When no error has occurred:
When an error has occurred:
For contents of error, refer to "Con-
tents of message" on the next page.
D-2: SELF CHECK
TEMP= ×××.×ûC
<CL>
D-2: SELF CHECK
CELL FAULT (C1)
<CL> <INC>
D-2: SELFCHECK
ALMCHECK
GOOD
<CL>
D-2: SELF CHECK
TEMP= ×××.×ûC
TEMP. ALARM
<CL>