43
Pin plug
Remove pin
plug fitted to
indicator.
Attachment
Mount the supplied
attachment on
indicator.
Studs
Indicator attached
to transmission
unit side.
Remove the transmission
unit side cover with
window and indicator.
Remove the terminal
unit side cover.
Mount the studs
supplied with the
attachment on
the terminal
block.
Connect the red wire (+)
of the indicator to CK+
and the black wire (-) of
the indicator to CK-, then
attach the cover with
window.
Indicator attached to
terminal board side.
Attach the cover.
➀
➁
➂
➃➄
➅➆
Change of field indicator position
It is sometimes preferable to mount the indicator on the terminal block side due to
installation location.
In such a case, the following mounting procedure should be followed for analog indicator.
CAUTION
Avoid the following procedure in an explosionproof area.
Digital indicator cannot be mounted on the terminal block side.