Fluke Rev. 4 Speaker User Manual


 
701/702
Users Manual
92
DC Current Output
RANGE RESOLUTION
MODELS 701 AND 702
% OUTPUT +% OF FULL SCALE
1 YEAR 2 YEAR
22 mA 1 µA 0.01% + 0.04% 0.02% + 0.06%
Maximum Burden Voltage: 24V
Temperature Coefficient: (0.003% of output + 0.003% of f.s.)/°C in the ranges -10 to 18°C and 28 to 50°C
Common Mode Error: 0.008% f.s/(Common Mode Volt)
Maximum Input Voltage: 30V dc
Specification applies for currents between 2 mA and 22 mA. For current below 2 mA, typical accuracy is 0.15% of full
scale.