2. sp and Hot S
22
(S Parameters & Hot S
22
)
Header Section Keywords:
ncal Number of calibration sequences of this type to run.
npts Number of frequency points to use during the calibration sequence. Increasing
this number will increase calibration time.
Legal values are (3, 15, 51, 101, 201, 401, 801, 1601 only
)
NOTE: Illegal value causes software to default to 51.
con Connector sypes for Port 1 and Port 2: Options:
MN, FN - Male/Female N type
MK, FK - Male/Female K
MS, FS - Male/Female SMA
if IF bandwidth: Legal values are 10, 30, 100, 300, 1000, 3000, 10000, 30000
NOTE: Illegal value causes software to default to 1000.
avgs Averages: (Optional). Software will set averaging to value (and turn on) during cal.
pow Source power setting: during cal, Source 1.
switch Setting for test set. Correponds to 0-15 settings.
Detail Section Keywords:
CAL, 1 First calibration
cal type Type of calibration to perform:
12 - 12 term
RR - Reflection Reverse
RF - Reflection Forward
8T - 1 Path 2 Port Forward
8R - 1 Path 2 Port Reverse
FT - Transmission Frequency Response
<name> Name for Hot S
22
<hot> For Hot S
22
only. Value = offset in kHz of 2nd Source
Table A-1. Technical Details of Calibration Specification Files (5 of 9).
Header
SP_START
SP_END
Details