System Description
Antenna Display Unit (Optional)
The Antenna Display Unit is a rack mountable (two rack height) antenna control unit (ADU) that is designed
to provide direct interface to a local area network to provide a remote control graphical user interface (GUI)
for the ACS3000 Antenna Control System. In addition to the rear panel interface connections, the ADU
provides a front panel mounted LCD display, keyboard, momentary action reset switch, power indicator,
summary fault alarm indicator, and display contrast adjustment allowing an alternate method for the operator
to control and determine status of the ACS3000 antenna Control System. The ADU is documented
separately in the Antenna Display Unit Users Guide.
Power/Environmental Description LMKVS-CPU
Operational Temperature: -40 to +50° C
If heater is off internal temperature must be 0° C
before operation can begin
Storage Temperature: -40 to +60° C
Relative Humidity: 0 - 100% Condensing
Enclosure Protection Class: NEMA 4X / IP56
Enclosure Type: EMI Protected Fiberglass
Control Interface Method: Ethernet
Dimensions: 26 1/2" W x 32" H x 14" D
Weight: 88 lbs
Approvals: EN 60950 (CE), EN 61326 Class A UL 60950, FCC
Part 15 Class A
Power: LMKVS-CPU-208
208 - 230 VAC, 60 Amps
3 Phase 50/60 Hz
No Neutral Required, Safety Ground Required
LMKVS-CPU-380
380 - 460 VAC, 30 Amps
3 Phase 50/60 Hz
No Neutral Required, Safety Ground Required
Power/Environmental Description Beacon Interface
Operational Temperature: 0 to +50° C
Storage Temperature: -40 to +60° C
Relative Humidity: 93 - 100% Non-Condensing
Enclosure Type: 1 RU Rack Mount Metal Enclosure
Control Interface Method: Ethernet