Andrew OMACS3000 Satellite Radio User Manual


 
11-APR-06 Rev E OMACS3000
42 of 51
System Screens
Figure 32: Logs Screen
Alarm Screen
The Alarms screen is a subset of the Logs screen. Selecting the Alarms screen will clear the alarm status
line in the Status Box if the alarm condition has ceased. With the Alarm acknowledged, the Status Box will
continue to show the flashing Alarm if an alarm condition still exists.
Alarm and Events Descriptions
The following messages appear in the Alarm/Logs screen. The Logs screen will record all events and the
Alarm screen will record only critical events.
"System not initialized"
System not initialized - operator must run the startup wizard.
“Java Sockets Counter went negative”
System closed more Java sockets then are allowed to be opened.
"No satellite table entries"
No satellite table is available - operator must input satellite table prior to tracking.
"Selected satellite is not visible"
Invalid satellite chosen or satellite is not visible - operator must choose another satellite.
"Invalid Beacon data"
No beacon receiver data is available - operator must reset hardware until beacon data is available.