Andrew OMACS3000 Satellite Radio User Manual


 
11-APR-06 Rev E OMACS3000
44 of 51
System Screens
"MCU error ON (or OFF) - Pol Direction".
Pol Direction. Axis is moving in the opposite direction of the commanded position.
"MCU error ON (or OFF) - MCU error On (or Off) - Az Current overload".
Az Current overload.
"MCU error ON (or OFF) - El Current overload".
El Current overload.
"MCU error ON (or OFF) - Pol Current overload".
Pol Current overload.
"MCU error ON (or OFF) - Az Resolver fault".
Az Resolver fault.
"MCU error ON (or OFF) - El Resolver fault".
El Resolver fault.
"MCU error ON (or OFF) - Pol Resolver fault".
Pol Resolver fault.
"Operator stop command issued ON (or OFF or MVRST or RESET".
Operator stop command issued where ON and OFF are normal stops while MVRST is issued just prior to
repeating a move request, usually a track move request, and RESET is issued when the MCU reset has
been selected.
"Motor movement stopped".
MCU detected motor movement stopped..
"Invalid Intelsat Track mode parameters"
Invalid Intelsat Track mode parameters - tracking turned off.
"Invalid NORAD Track mode parameters"
Invalid NORAD parameters - tracking turned off.
"Low beacon level"
Beacon level fell below low signal level - tracking turned off if no valid model is available or if in step tracking.
"cccccccccc mode requested - no valid satellite selected"
Where ccccccc is the Track mode requested when no valid satellite is selected - tracking turned off.
"SmarTrack® model available"
SmarTrack® model is available.
"NORAD track look angels not reachable"
NORAD track look angles are not reachable - tracking turned off.
"Intelsat track look angels not reachable"
Intelsat track look angles are not reachable - tracking turned off.
"SmarTrack® look angels not reachable"
SmarTrack® look angles are not reachable - tracking turned off.
"Step track look angels not reachable"
Step track look angles are not reachable - tracking turned off.